Electra OU7-24 RC Servisní příručka Strana 56

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 168
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 55
11-1
CONTROL SYSTEM
Revision Y06-02Service Manual - KN Series
11. CONTROL SYSTEM
11.1 Electronic Control
11.1.1 Introduction
The electronic control information is designed for service applications, and is common
to the following groups of air-conditioners:
x ST/RC group -Cooling only / cooling and heating by heat pum p.
x SH group -Cooling and heating by heat pump and supplementary heater.
x RH group -Cooling, heating by heaters only.
11.1.2 Remote Control DIP Switch Settings
DEFINITION SETTING SWITCH STATUS
RC4 RC3
SW.
NO. 4
SW.
NO. 3
SW.
NO. 2
SW.
NO. 1
RC-ALL MODES OF OPERATION ----OFFOFF
STD-COOL, FAN, DRY, ACTIVE ----OFFON
HEAT-COOL, FAN, DRY, ACTIVE ----ONOFF
AUTO FAN (AF) ----ONON
VERTICAL SWING ONLY
TEMP. DISPLAY IN qC DEGREES
--OFF----
HORIZONTAL & VERTICAL
SWING FUNCTIONS
TOGETHER
TEMP. DISPLAY IN qF DEGREES
--ON----
DISABLE LCD & KEY
ILLUMINATION
TIMER & CLOCK 12H AM, PM OFF------
ENABLE LCD & KEY
ILLUMINATION
TIMER & CLOCK 24H ON------
Reset operation - Press the 4 buttons simultaneously: “CLEAR “, “SET”, "HR +”, ”HR -”
for 5 seconds
LEGEND
SW1, SW2 - Selection of RC/ST
SW3 – Selection of Display qC or qF in RC3 or swing function in RC4
SW4 – Selection of Time Display 12H AM/PM or 24H in RC3 or illumination in RC4
OFF = 0
ON = 1
NOTE
After setting the DIP switches perform reset operation.
CONTENT
Zobrazit stránku 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 167 168